ICE982S

$1,299.90

Solar Station – ICE982S

SKU: ice-ss-982s Category:

Description

1, Features:

  •  Application capacity
  • Max.number of collectors: 2
  • Max.number of storage tanks: 2
  • Max.number of relays: 4
  • Max.number of sensors: 7
  • Max.number of application system: 15

 

2, Technical datas:

1 Dimension:  420x280x155mm
2 Power  supply: 200V-240V  AC  or  100V-130V  AC,50-60Hz.  .      
3 Power  consumption:  < 3W 
4 Accuracy of temperature measuring: ± 2oC
5 Range of collector temperature measuring: -10oC ~200oC
6 Range of tank temperature measuring: 0oC ~100oC
7 Suitable power of pump: 3 pumps possible to be connected, power of each pump < 200W . 
8 Suitable power electrical heating:1 relay for 1500W(1500w-4000w must be use SR802)
9 Inputs: 5sensors, 
       7pcs*Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC),
       4pcs*NTC10K, B3950 sensor (≤ 135oC) for tank, (PVC cable ≤105oC), 
10 Outputs:4 relays, for circulation pumps or 3-way electromagnetic valve 
11 Ambient temperature:-10oC ~ 50oC.
12 Water proof grade: IP42.

 

3, Main functions:

1 Pump  support: Normal  Pump or high  efficiency  pump
2 Set  up  clock/week
3 THET  Timing  heating 37
4 CIRC  DHW  circuilation  function  activated  /deactivated
5 tCYC  Tempeature  or  time  setting  for  DHW  pump  in  three  time  sections
6 DT  Temperature  difference  for  solar  circuit  pump
7 EMOF  Maximum  switch-off  temperature  of  collector  (for  collector  emergency  close  function)
8 CMX  Maximum  limited  temperature  of  collector  (collector  cooling  function)
9 CMN  Low  temperature  protection  of  collector
10 CFR  frost  protection  temperature  of  collector
11 REC  Recooling  temperature  of  tank
12 SMX1  Maximum  temperature  of  tank  1
13 SMX2  Maximum  temperature  of  tank  1
14 MAX1  Maximum  switch-off  temperature  for  heat  transfer  between  tank  and  heat  return
15 MIN1  Minmium  switch-on  temperature  for  heat  transfer  between  tank  and  heat  return
16 MAX2  Maximum  switch-off  temperature for  heat  transfer  between  heat  exchanger  and  tank
18 MIN2  Minmium  switch-on  temperature for  heat  transfer  between  heat  exchanger  and  tank
19 C_F  Switch  between  Celsius  and  Fahrenheit
20 DVWG  Anti  legionnaires’  function
21 SFB  Switch-on/off  of  the  solid  fuel  boiler
22 SFON  Minimum  switch-on  temperature  of  tank
23 SFOF  Maximum  switch-off  temperature  of  tank
24 MAX3  Maximum  switch-off  temperature  of  solid  fuel  boiler
25 MIN3  Minimum  switch-on  temperature  of  solid  fuel  boiler
26 PUMP1  P1  pump  operation  mode  selection
27 PUMP2  P2  pump  operation  mode  selection
28 OHQM  Thermal  energy  measuring
29 FTYPE  Flow  meter  type  selection
30 FMAX  Flow  rate
31 MEDT  Type  of  heat  transfer  liquid
32 MED%  Concentration  of  heat  transfer  liquid
33 Tank  priority
34 Pump  Intermission  function
35 COOL  Tank  cooling  function
36 AHO  Automatical  thermostat  function
37 BYPR  Bypass  function  (high  temperature)<38> HND  Manual  control
39 PASS  Password  set
40 REST  Recovery  to  factory  set
41 “ON/OFF”Controller  switch  on/off  button
42 Holiday  function
43 Manual  heating
44 Temperature  checking  function
45 Protection  function
46 Memory  protection
47 Screen  protection
48 Pump  P1/P2  dry  running  protection
49 Trouble  shooting
50 Trouble  protection
51 Trouble  checking